Standard Options¶
The standard options are predefined features that modify a standard burner structure in a planned manner. Each option has its own item number and makes the burner item number optional meaning that a letter T will appear at the end of burner item number. The most common options are explained below:
Extended combustion head¶
Longer combustion head for boilers where the standard combustion head is too short
Extension plate¶
Spacer used between the combustion head and the boiler when the combustion head is too long for the boiler
Continuous operation¶
Equipment required for operating the burner continuously without breaks
Variable speed drive¶
Controller that allows burner automation to adjust fan speed dynamically based on the required capacity
Ignition gas piping¶
Pipework that supplies gas to the ignition burner
Deaerator for light fuel oil¶
Device that removes air and gas bubbles both from supply oil and recirculated oil
LPG gas nozzle¶
Nozzles for firing liquefied petroleum gas
Flue gas recirculation (FGR)¶
The use of flue gas from the combustion process and recirculating it back through the burner and boiler
Gas pressure gauge¶
Gauge for checking ignition gas pressure
Fan pressure gauge¶
Gauge for measuring the pressure generated by the fan
Pressure gauge for oil inlet pressure¶
Pressure gauge for oil supply
Oil pressure switch (nozzle and return)¶
Minimum pressure switch (nozzle) or maximum pressure switch (return). If a pressure limit is reached, the burner will stop.
Oil pressure transmitter (nozzle and return)¶
Transmitter for the minimum or maximum pressure switch
Oil temperature transmitter (nozzle)¶
Transmitter for monitoring that the oil reaches a sufficient atomizing temperature. Used with heavy fuel oil. Stops the burner if the temperature is insufficient.
Gas pressure switch, max.¶
A safety component that prevents the CO concentration from reaching hazardous levels. Stops the burner if the gas pressure is too high.
220/380 V, 60 Hz¶
The necessary components for using the burner with a different voltage level
60 Hz frequency¶
Fan wheel and air cone for 60 Hz operation
O2 WDx00i¶
Power source for an O2 module, for use in a control cabinet integrated in the burner
Load control (RWF)¶
Capacity controller for WD600i burners
Heating cartridges¶
Heating cartridges reduce the viscosity of heavy fuel oil, allowing the oil to flow through narrow sections in the pipework and into the burner’s oil heating circuit.
Gas nozzle option¶
Gas nozzle configuration for various uses